Figure 4-36. Water heater control panel box with cover removed.
e. Water Heater Control Panel Box.
that attaches the pressure and temperature control (12,
(1) Removal.
(e) Remove the conduit nuts (2 and 3,
remove the circuit breaker subassembly.
fig. 4-36) that attach the conduits to
the panel box.
(f) Remove the box connector (4) that
remove the control box receptacle connector.
attaches the solenoid valve to the panel box.
(c) Disconnect the two wires connected
(g) Remove the nuts and screws that
to the pressure and temperature control.
attach the water temperature gage bracket to the panel
NOTE
box, and separate the bracket from the panel box.
Tag the wires for identification if
(h) Remove the nuts (9) and the ground
color-coded wires are not used.
wire from the capscrews that hold the panel box to the