TM 10-4510-207-14
2.6.4.
Hose Connections.
a.
If using natural or open water source, assemble water supply strainer (1) and spring check valve
assembly (2). Note that flow direction of check valve is away from strainer.
b.
Connect supply hose (3) (1 inch diameter X 35 feet long) to spring check valve assembly (2) if using
natural or open water source, or to closed water supply connection point. If using natural or open water
source, position hose with supply strainer (1) into water so that strainer is completely submerged. If
using a closed water supply, be sure supply valve is closed.
c.
If needed to reach pump assembly (4), connect supply hose (5) (1 inch diameter X 25 feet long) to supply
hose (3).
d.
Connect supply hose (3 or 5) to supply pump inlet (6).
e.
Connect supply hose (7) between temperature regulator outlet (8) and regulator valve assembly (9) inlet.
Note that flow direction of regulator valve is away from pump assembly.
f.
Connect supply hose (10) (1 inch diameter X 35 feet long) between regulator valve assembly (9) outlet
and showerhead manifold assembly (11). Note that supply hose passes through opening in shower cover.
g.
Connect six supply hoses (12) between each showerhead manifold assembly (11) as shown. Connect
supply hose ends together over entrance to shower facility away from pump assembly to form a crossover
pipe. Note that supply hose pass through opening in shower cover.
h.
Install attached cap (13) onto open end of last showerhead manifold assembly.
i.
Connect two drain hose (14) onto Y-fitting coupler (15).
j.
Connect drain hose (16) (2 inch diameter X 35 feet long) between Y-fitting coupler (15) and diaphragm
(drain) pump inlet (7).
k.
Connect drain hose (18) to diaphragm (drain) pump outlet (19). Connect opposite end of hose to waste
water connection point (storage tank) or route to waste water disposal site.
l.
Connect supply hose (20) (1 inch diameter X 5 feet long) to supply pump outlet (21).
m. Connect supply hose (22) (1 inch diameter X 12 feet long) to hot water inlet (23).
n.
Connect supply hoses (20 and 22) to portable hot water system (24). Refer to technical manual covering
he portable hot water system to find specific connection requirements for it.
o.
Notify unit maintenance to connect two fuel hoses (25) to portable hot water system (24). Refer to
technical manual covering the portable hot water system to find specific connection requirements for it.
2-12