TM 10-4510-208-13&P
0018 00
Table 1. Water Troubleshooting Procedures-Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check to ensure water feed is
Step 1. Ensure water service feed is
4. NO WATER FROM 30
connected properly.
connected to water source and water
GPM WATER PUMP
is available at the source.
(Containerized Shower
Check all valves to make sure they
only)
are open.
Ensure water hose connections are
tight.
Reconnect power connections as
Step 2. Ensure power connections
necessary.
to the shower and pump are secure
Reset tripped circuit breakers by
Ensure the main breaker (No.7/9/11)
switching them OFF, then ON.
and the pump breaker (No.2/4/6) on
the circuit breaker panel are ON.
Step 3. Ensure that pump is turned
Press OFF (red) button on motor
ON at the motor controller.
controller, then press ON button
(green).
Operate pressure switch override
until pressure reaches 20 psi on
gauge.
Step 4. Ensure that pump is primed.
Turn pump OFF at motor
controller by pressing the red
button.
Turn OFF circuit breaker No.2/4/6
at the shower circuit breaker
panel. Prime pump (refer to WP
Reset circuit breaker No.2/4/6 by
switching OFF, then ON.
Turn pump ON by pressing the
green button on the motor
controller.
Operate pressure switch override
until pressure reaches 20 psi on
gauge.
Step 5. Ensure that pump is rotating
Notify Unit Maintenance.
in the proper direction.
0018 00-7