Table 1. Water Troubleshooting Procedures-Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. NO WATER FROM 30 GPM
Step 6. Ensure that strainer is
Turn pump OFF at motor
WATER PUMP - continued
clear.
controller by pressing the red
(Containerized Shower only)
button. Turn OFF circuit breaker
No.2/4/6 at the shower circuit
breaker panel. Secure water
supply at water tank (refer to TM
10-5430-237-12&P).
Remove strainer element, clean,
and reinstall. Open water supply
at water tank. Turn ON circuit
breaker No.2/4/6. Turn ON motor
controller by pressing the green
button. Operate pressure switch
override until pressure reaches
20 psi on gauge.
If problem persists, notify unit
maintenance.
Circuit Breakers
Pressure Switch
Pressure
Switch
Override
Motor
Pressure
Controller
Gauge
ON
Strainer
OFF
Strainer Element
Direction of Rotation
0018 00-8