TM 10-4510-208-13&P
0020 00
THIS SECTION COVERS:
PMCS Checks and Services, Containerized Shower 30 gpm Water Pump
INITIAL SETUP:
Containerized Shower set up
Maintenance Level
Operator
Table 1. Preventive Maintenance Checks and Services for Containerized Shower
and Shower, Enclosed Unit, System - continued
WARNING
Protective clothing and equipment must be worn. Heavy-duty rubber apron, rubber gloves, safety
splash goggles and/or face shield are required when potential exists for contact with waste water or
contaminated surfaces. Wastewater and surfaces may be contaminated with pathogenic
microorganisms, bacteria or viruses that present a risk of serious illness or death to personnel.
Item To Be
Equipment
Item No.
Interval
Checked Or
Procedure
Not Ready/
Serviced
Available If:
Pump assembly or any
8
Before
30 gpm Water
Inspect pump assembly (1) and
component damaged.
Pump
components for material damage.
Pressure switch (3)
Check pump frame (2) for bends and
damaged or wiring
cracks. Check all pipe connections
exposed. Motor starter
on pump assembly for leaks. Ensure
(4) damaged or wiring
that all components are secure in
exposed. Pressure
pump frame (2). Check that pump is
tank (5) damaged or
securely placed and will not slide.
leaking water or air.
Pressure tank or pump
motor (6) loose in
pump frame.
Visible water leaks
from any component.
Pump operating out of
Monitor pump operation. Check
9
During
30 gpm Water
parameters for
Pump
water pressure gauge (7) to ensure
pressure. Class III
that pump cycles on at 20 to 25 psi
water leaks. Water
and off at 40 to 45 psi. Check for
discharge from
leaks on all pump assembly
pressure relief valve
components. Check for water
(8).
discharge from pressure relief valve
(8).