Table 1. Preventive Maintenance Checks and Services for Containerized Shower
and Shower, Enclosed Unit, System - continued
WARNING
Protective clothing and equipment must be worn. Heavy-duty rubber apron, rubber gloves, safety
splash goggles and/or face shield are required when potential exists for contact with waste water or
contaminated surfaces. Wastewater and surfaces may be contaminated with pathogenic
microorganisms, bacteria or viruses that present a risk of serious illness or death to personnel.
Item To Be
Equipment
Item No.
Interval
Checked Or
Procedure
Not Ready/
Serviced
Available If:
6
Weekly
Graywater tank
Graywater tank soiled or
Turn sump pump (5) OFF. Flush
clogged.
graywater tank (10) with chlorine
solution by pouring solution in shave
stand sinks (7) and allow to drain. Let
solution sit in tank for at least one
hour. Turn sump pump ON, and allow
Graywater tank soiled or
7
During, After
Clean graywater tank (10) after 30
clogged.
days continuous service, or prior to
preparing the shower for storage or
0020 00-10