TM 10-4510-208-13&P
0034 00
REPLACE
Replace a Damaged Fan Assembly
1. Unplug fan power cord (1) from the twistlock outlet (2) on the power service panel (3).
2. From inside the shower, remove nuts (4) and bolts (5) securing the exhaust fan (6) to mount (7)
(Containerized Shower only).
WARNING
The exhaust fan is heavy, awkward, and difficult to maneuver. Two persons should be
stationed on the container roof to handle the exhaust fan, and two on the ground.
3. Using hinged steps, climb on top of the shower container, remove bolts (5) from exhaust fan (6)
(Shower, Enclosed Unit, System only) and then remove exhaust fan from mount (7).
4. Place operational fan on mount (7), aligning holes (8).
5. Install the fan mounting bolts (5) (Shower, Enclosed Unit, System only).
6. From inside the shower, install nuts (4) onto exhaust fan mounting bolts (5) (Containerized Shower
only).
7. Plug power cord (1) into twistlock outlet (2) on power service panel (3).
6
5
1
6
2
5
8
3
7
Containerized Shower
4
3
2
Containerized Shower
Shower, Enclosed
Unit, System
Shower, Enclosed Unit, System
END OF WORK PACKAGE
0034 00-2