TM 10-4510-208-13&P
UNIT MAINTENANCE
CONTAINERIZED SHOWER
SHOWER, ENCLOSED UNIT, SYSTEM
EXHAUST FAN ASSEMBLY
TEST, REPLACE
INITIAL SETUP
Tools
Personnel Required
Shop Equipment Automotive Maintenance and
Four
Repair: Organizational Maintenance, Common
Equipment Condition
Containerized Shower / Shower, Enclosed Unit,
System set up
Materials/Parts
Circuit breaker No. 1. (Containerized shower only)
set to the OFF position. Apply tag or unplug cord
(Shower, Enclosed Unit, System).
TEST
Test Exhaust Fan
1. Set main breaker No. 7/9/11 and circuit breaker No. 1 to the ON position (Containerized Shower
only).
2. Turn exhaust fan switch ON.
WARNING
Do not attempt to clear objects from installed fan with fingers, tools, or foreign objects.
Fan blades can cause serious injury or death by cutting or by missile hazard.
3. Exhaust fan should come on without delay. Monitor for unusual sounds that might come from
mechanical failure or foreign objects in contact with fan blades (1). Monitor for unusual levels of
vibration.
4. Malfunctioning or damaged exhaust fans must be replaced.
1
0034 00-1