TM 10-4510-209-13&P
0047 00
Replace Electrical Panel Convenience Outlet (CLS only)
WARNING
ELECTRICITY CAN KILL YOU. The latrine is a wet environment capable of poising an
electrical shock hazard when personnel have direct contact with energized wires or metal
parts. Electricity is unlike most hazards; its effect is immediate. Failure to use extreme
caution may result in serious injury or death to personnel.
1. Disconnect power.
2. Remove screws (1) from faceplate (2) and remove gasket (3) and faceplate.
3. Remove two screws (4) holding outlet (5) to container.
4. Pull outlet (5) out enough to provide access to the wires (6).
5. Tag and disconnect wires (6), and remove outlet (5).
6. Connect wires (6) to the replacement outlet (5) as tagged.
7. Install new outlet (5) and retain with screws.
8. Place gasket (3) and faceplate (5) into position and retain with screws (4).
9. Reconnect power, and test for normal operation.
3
2
1
6
5
4
0047 00-14