TM 10-4510-209-13&P
0047 00
Replace Water Supply Pump Outlet (CLS only)
WARNING
ELECTRICITY CAN KILL YOU. The latrine is a wet environment capable of poising an
electrical shock hazard when personnel have direct contact with energized wires or metal
parts. Electricity is unlike most hazards; its effect is immediate. Failure to use extreme
caution may result in serious injury or death to personnel.
NOTE
A step aid may be required to perform this maintenance task.
1. Disconnect power.
2. Remove four retaining screws (1) from faceplate (2) and remove faceplate.
3. Remove two screws (3) holding outlet (4) to wire raceway (5).
4. Pull outlet (4) out enough to provide access to the wire connections.
5. Tag wires (6) and remove outlet (4).
6. Reconnect wires (6) to replacement outlet (4) as tagged.
7. Install outlet (4) and retain with screws (3).
8. Install faceplate (2) and retain with screws (1).
9. Reconnect power and test for normal operation.
2
1
5
6
4
3
0047 00-16