TM 10-4510-209-13&P
0047 00
Replace ECU Outlet
WARNING
Always secure and tag circuit breakers in the OFF position or disconnect equipment's
power cord from receptacle before attempting any electrical repairs, even minor repairs.
The latrine is a wet environment capable of posing an electrical shock hazard when
personnel have direct contact with energized wires or metal parts. Failure to observe this
safety warning may result in serious injury or death to personnel.
1. Disconnect power.
2. Remove four retaining screws (1) from faceplate (2) and remove faceplate.
3. Remove two screws (3) holding outlet (4) to wire raceway (5).
4. Pull outlet (4) out enough to provide access to wire connections.
5. Tag wires (6) and remove outlet (4).
6. Reconnect wires (6) to replacement outlet (4) as tagged.
7. Install outlet (4) and retain with screws (3).
8. Place faceplate (2) into position and retain with screws (1).
9. Reconnect power and text for normal operation.
3
2
1
5
6
4
0047 00-17