TM 10-4510-209-13&P
0048 00
REPLACE
Replace the P-Traps
WARNING
Protective clothing and equipment must be worn. Heavy-duty rubber apron, rubber
gloves, safety splash goggles and/or face shield are required when potential exists for
contact with wastewater or contaminated surfaces. Wastewater and surfaces may be
contaminated with pathogenic microorganisms, bacteria or viruses, which present a risk
of serious illness or death to personnel.
1. Unscrew the drain plug (1), and allow P-trap to drain. Remove any obstructions.
2. Ensure urinal or sink(s) being serviced have been emptied.
3. Unscrew the two union fittings (1) retaining the P-trap (2).
NOTE
P-trap being serviced may drip/drain once the drain plug is removed. A bucket or
absorbent material may be required to absorb liquid.
4. Remove the P-trap (2).
5. Install the replacement P-trap (2), and retain with two unions (1). Do not overtighten.
1
2
END OF WORK PACKAGE
0048 00-3/(4 Blank)