TM 10-7360-226-13&P
0018 00
CONTAINERIZED KITCHEN (WITH TRAILER)
UNIT MAINTENANCE PROCEDURES
Remove the flexible exhaust pipe at the top of the generator. Remove and retain the hold
down plates at the base of the generator. Leave the exhaust plenum attached the top of the
generator.
A forklift is required to remove the generator from the Mechanical Room. Using a forklift of
adequate capacity, remove the generator from the Mechanical Room being careful that that the
generator clears the air conditioner brackets and the doorway.
Install all loose doors and hinges to the generator. Remove and retain the exhaust plenum.
Install: Attach the exhaust plenum to
the top of
the generator. Remove the control panel door
and right side access door, leaving the hinges attached to the doors.
A forklift is required to install the generator into the Mechanical Room. Using a forklift of
adequate capacity, install the generator into the Mechanical Room being careful that that the
generator clears the air conditioner brackets and the doorway.
Attach the generator hold down plates using retained hardware. Connect the power cables to
Install the hold-down brackets at the base of the generator set. Install the flexible exhaust pipe
to the top of the generator. Place the previously removed access doors between the kitchen
wall and the generator set. Close the mechanical room access doors.
END OF WORK PACKAGE