TM 10-7360-226-13&P
0026 00
CONTAINERIZED KITCHEN (WITH TRAILER)
UNIT MAINTENANCE PROCEDURES
Main Control Panel:
Switch/Lamp Replacement: Make sure the external power source is disconnected and the
generator is shut down. Referring to Figure 4, label and remove the spade lugs from the
switch/lamp to be replaced. Remove the mounting hardware from the front of the panel and
remove the switch/lamp assembly. Install the replacement switch/lamp assembly, replace
hardware and reconnect spade lug terminals.
EXTERNAL
POWER
POWER
AVAILABLE
AVAILABLE
SYSTEM POWER SELECTION
EXTERNAL
OFF
POWER ON
POWER ON
NORMAL
ON
ON
BLACKOUT
OFF
OFF
INTERIOR
LIGHTING
EM RGENCY
E
LIGHTING
MODE
LIGHT
Figure 4. Main Control Panel.
0026 00-5
Change 1