TM 5-6350-255-13
CHAPTER 2
OPERATING INSTRUCTIONS
trouble to organizational maintenance personnel
WARNING
If equipment fails to operate, refer
Section I. 0PERATING PROCEDURES
2-1. Operation of Security Switches
position, allows recovery of the armed unit without
CAUTION
positioned to a letter-number code unique to the
Position, the sensor disable system is
particular unit. The code is printed inside the battery
activated. Any movement or tilting of the
compartment and/or the wiring side of the code plug.
sensor case will permanently damage the
The code must be recorded on the identification tag (fig.
Figure 2-1. MINISID III, controls (Models AN/GSQ-154 (V) and AN/GSQ-154A (V).
b.poor visibility conditions, the above mentioned settings
counterclockwise position. Begin rotating this knob slowly
can be accomplished by feel in the following manner:
clockwise. Listen for each click as you rotate the knob
(1)
Orient yourself with respect to the
clockwise. First click is the letter "A", second click is "B",
MINISID III location.
etc., through "J". Stop on the required security code letter
(2) Feel the outlines of MINISID III and take a
position.
position where MINISID III is in front of you with the
(4) Locate, by touch, the knob located at the center
antenna protruding to the right side.
position. Verify that knob is in the full counterclockwise
(3) Locate, by touch, the knob located at the
position. Listen for clicks. First click is "1", second click is
leftmost position.Verify that the knob is in the full
"2", etc., through "10". Stop at the correct security
code number setting.
2-1