TM 10-3510-226-23
0022 00
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
POWER OUTPUT RECEPTACLE
TEST, REPLACE
INITIAL SETUP
Tools
Personnel Required
Shop Equipment, Automotive Maintenance and
Quartermaster and Chemical Equipment
Repair: Organizational Maintenance, Common No.1
Repairer 63J (1)
Materials/Parts
Equipment Condition
CBL set up
Main Breaker OFF
TEST
Test the Power Output Receptacle
WARNING
This equipment operates at high voltages. Use extreme caution, observe all warnings,
and follow all safety procedures. Failure to observe safety precautions may result in
injury or death to personnel.
1. Disconnect power output cable (Figure 1, Item 1) from the receptacle (Figure 1, Item 2) on the CBL
power panel (Figure 1, Item 3).
2. Remove screws retaining the main circuit breaker box cover (Figure 2, Item 4) and remove the circuit
breaker box cover.
3. Remove screws retaining the circuit breaker panel cover (Figure 2, Item 5) and remove the circuit
breaker panel cover.
4. At the rear of the power panel (Figure 1, Item 3), remove the panel cover and then unscrew the
retainer (Figure 1, Item 6) and pull the receptacle (Figure 1, Item 2) out of the sleeve (Figure 1,
Item 7).
5. Use an ohmmeter to check for zero resistance between each prong (Figure 1, Item 8) and the
corresponding wire connection (Figure 1, Item 9) on the output circuit breaker (#23, 25, 27) (Figure
1, Item 10).
6. Check for secure connection and condition of wiring with an open connection between the prong
(Figure 1, Item 8) on the receptacle (Figure 1, Item 2) and the output circuit breaker (#23, 25, 27)
(Figure 1, Item 10).
7. Replace a receptacle (Figure 1, Item 2) and/or wiring with an open connection as described under
REPLACE.
8. If continuity is determined between each prong and the corresponding circuit breaker connection, re-
install the receptacle (Figure 1, Item 2), secure with retainer (Figure 1, Item 6), and install the panel
cover.