TM 10-3510-226-23
0022 00
REPLACE
Replace the Power Output Receptacle
WARNING
This equipment operates at high voltages. Use extreme caution, observe all warnings,
and follow all safety procedures. Failure to observe safety precautions may result in
injury or death to personnel.
1. Disconnect the output power cable (Figure 2, Item 1) from the receptacle (Figure 2, Item 2) on the
CBL power panel (Figure 2, Item 3)
2. At the rear of the power panel (Figure 2, Item 3), remove the panel cover and then unscrew the
retainer (Figure 2, Item 6) and pull the receptacle (Figure 2, Item 2) out of the sleeve (Figure 2,
Item 7).
6
1
2
3
3
7
2
4
3
Figure 2. Replace the Power Output Receptacle.
0022 00-3