TM 10-3510-208-12
Section XIV. TRANSFORMER, HANDY BOX AND SOLENOID
the handy box and transformer.
REMOVE COVER AND TAG AND DISCONNECT
ELECTRICAL LEADS AS NECESSARY.
TS 3510-208-12/4-48
Figure 4-48. Ignition transformer and handy box, removal and installation
Clean metal parts with cleaning solvent, Fed.
b. Cleaning.
Spec. P-D-680, and dry thoroughly.
Clean parts in a well-ventilated area. Avoid
c. Inspection and Repair.
(1) Inspect all parts for damage.
inhalation of solvent fumes and prolonged
exposure of skin to cleaning solvent. Wash
(2) Replace all damaged parts.
exposed skin thoroughly. Dry cleaning
the transformer and handy box.
solvent (Fed. Spec. P-D-680) used to clean
parts is potentially dangerous to personnel
and property. Do not use near open flame or
excessive heat. Flash point of solvent is 100
to 138F. (38 to 59C.).
6-61