TM 10-3510-208-12
TS 10-3510-206-12/4-69 (Sheet 2 of 2)
13. Screw
8. Screw
14. Contact
9. Heater
15. Contact
10. Screw
16. Spring
11. Clamp
12. Contact
Figure 4-69. Tumbler controls, disassembly and reassembly (sheet 2 of 2).
(5) Install the terminal block (6) on the
c. Cleaning. Clean all parts of the tumbler
controls, using dry compressed air and a clean
control panel (7) and secure with screws (5).
(6) Install the relay (4) on the control panel
cloth.
and secure with screws (3).
d. Inspection.
(7) Install the fuse box (2) on the control
(1) Inspect all parts of the tumbler controls
panel (7) and secure with screws (1).
for cracks, chips, dents, and other damage.
g. Installation.
(2) Inspect all hardware for thread damage.
(1) Install the switch assemblies (20, fig.
e. Repair.
(1) Weld cracks or breaks and straighten
and nuts (17).
dents.
(2) Install the switch box cover (16) and
(2) Replace damaged controls and/or parts
therein, and hardware.
f.
Assembly.
(3) Install the keepers (18) and locknuts (12).
(1) Insert the contact springs (16, fig. 4-69),
(4) Install the control panel assembly (11) and
then press the contacts (15) into position within
secure with lockwashers (10) and screws (9).
the retaining clips.
(5) Install the timer (8) and secure with
keeper (7), spacers (6), screws (5) and nuts M).
(2) Install the contacts (14) into the relay
(6) Reconnect all disconnected wiring.
switch boxes and secure with screws (13).
(7) Install the panel cover (3) and secure with
(3) Install the contacts (12) into the relay
switch boxes and secure with terminal clamps (11)
lockwashers (2) and screws (1).
and screws (10).
4-53. Timing and Alarm Device
(4) Install the thermal release heaters (9) into
a. Removal.
the relay switch boxes and secure with screws (8).
4-96