TM 10-3510-208-34
3.
AN/URM-105. Read the upper, black,
straight-lined portion of the "AC and DC volts" scale for
the range the selector switch is set at.
Switch Setting
Scale
1000 DC Volts...........................0-10 (and multiply by
100)
100 DC Volts.............................0-10 (and multiply by
10)
10 DC Volts...............................0-10
1 DC Volt ..................................0-10 (and divide by 10)
Thus, the meter (fig. 2-9, sheet 3 of 3) is showing the
following readings:
Figure 2-9. Reading DC voltage (sheet 3 of 3).
d.
If the AC Volts Scale is Used. The AC
volts scale is used to measure the 115 AC voltage.
(1)
Before
using
the
multimeter
to
measure 115 AC voltage, do the following steps that
match the multimeter you have. (refer to figure 2-10).
(a)
AN/URM-105. Set meter switch
to "1000 AC volts".
2-16