TM 10-3510-209-10
2-7. SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(2)
Remove two wingnuts (2) and remove bracket assembly (1).
(3)
Remove water pump (3) and locate it no more than 10 feet (3 m) from the water source.
(4)
Install bracket (1) and tighten wingnuts (2) removed in step (2).
(5)
Connect suction hose (1, FIG. 2-10) to suction inlet (2).
WARNING
Ensure that water hoses (1 and 4, FIG. 2-10) do not touch or cross other
water hoses, exhaust ducts, power cables, or fuel lines. Melting/
damage can occur causing leaking fuel and water or electical hazards.
Death by electrocution, fire, or explosion could result.
(6)
Connect suction strainer (3) to the other end of suction hose (1). Position the strainer in the water
source above the stream bed. Make a tripod from tree branches or saplings and hang the strainer
from the place where the branches are tied together, or position the strainer on a bed of stones or
gravel.
(7)
Connect water heater intake hose (4) to water pump discharge outlet (5).
(8)
Connect the other end of water heater intake hose (4) to water heater inlet (6).
(9)
Deleted
2-38 Change 1