TM 10-3510-209-10
2-7. SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(10)
Ensure petcock valve (7) on water pump housing is closed. Clockwise rotation closes valve.
(11)
Ensure petcock valve (8) and drain valve (9) on the water heater are closed. Clockwise
rotation closes valve.
(12)
Ensure washer inlet hose (10) is connected to washer inlet (11) and to water heater outlet
(12).
(13)
Ensure that hose (13) from water heater inlet (6) is connected to piping assembly (14).
(14)
Ensure that drain hose (1, FIG. 2-11) is connected to extractor drain connection (2) and
washer drain connection (3).
WARNING
Ensure that drain hoses (4 and 6, FIG. 2-11) do not touch or cross other water
hoses, power cables, exhaust ducts, or fuel lines. Melting/damage can occur
causing leaking fuel and water or electrical hazards. Death by electrocution, fire,
or explosion could result.
(15)
Connect one 25-foot (7.6 m), 1-1/2-inch-diameter drain hose (4) to pre-extraction bin drain
(5) and route the hose to a drain field. Do not touch or cross other water hoses, power
cables, exhaust ducts, or fuel lines.
(16)
Connect one 25-foot (7.6 m), 2-1/2-inch-diameter drain hose (6) to washer drain (7) and route
the hose to a drain field. Do not touch or cross other water hoses, power cables, exhaust
ducts, or fuel lines.
d.
Set up electric power cables as follows:
WARNING
The laundry unit uses 208 V ac. All circuit breakers on the electrical panel must be
off prior to connecting electrical power cables. Failure to observe safety
precautions may result in death or serious injury.
(1)
Open electrical panel door (1, FIG. 2-12) and turn off all circuit breakers (2).
(2)
Remove dust cap (3) on main power connection (4).
Change 1 2-40