TM 10-3510-209-10
2-7. SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(3)
Connect main power cable (5) to main power connection (4). Connect other end of power
cable to power source. Refer to TM 5-6115-585-12 for electrical connections on generator.
WARNING
Ensure that power cable (6, FIG. 2-12) does not touch or cross water hoses,
exhaust ducts, or fuel lines. Melting/damage can occur causing leaking fuel and
water or electrical hazards. Death by electrocution, fire, or explosion could result.
NOTE
Lock power cables in place by rotating connector clockwise.
(4)
Connect water pump cable (6) between water heater service outlet (7) and water pump
service outlet (8). Do not touch or cross water hoses, exhaust ducts, or fuel lines.
(5)
Ensure water pump ON/OFF switch is in the OFF position.
(6)
Ensure water heater load limit switch is in the OFF position.
Change 1 2-40.1/(2-40.2 blank)