TM 10-3510-209-24
2-37. WATER HEATER FUEL PUMP ASSEMBLY
This task covers:
a. Inspection
b. Removal
c. Repair
d. Installation
e. Adjustment
INITIAL SETUP
Tools
General Safety Instructions
General mechanic's tool set,
SC 5180-90
WARNING
Wrench, pin, 1-inch
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective
goggles and gloves and use only in a well-ventilated area. Avoid contact
with skin, eyes, and clothes and don't breathe vapors. Do not use
Personnel Required
near open flame or excessive heat. The flash point is 100-138° (38--59°C).
MOS 63J (1)
If you become dizzy while using cleaning solvent, get fresh air
immediately and get medical aid. If contact with eyes is made, wash your
Materials/Parts
eyes with water and get medical aid immediately.
Drycleaning solvent
(Item 10, .App C)
Equipment Condition
TM 10-3510-209-10, Tarp assembly removed.
INSPECTION
Inspect fuel pump for leaks, noise, and unusual vibration during operation.
Change 1 2-129