TM 10-3510-209-24
2-36. WATER HEATER BLOWER AND MOTOR ASSEMBLY (CONT)
REMOVAL (Cont)
INSTALLATION
1.
Install conduit connector (27) in junction box (28)
and secure with nut (26).
2.
Connect wires (25) in junction box (28).
Removes tags. See FIGURE 2-5.
3.
Install cover plate (24) on back side of blower
assembly and secure with two screws (23).
4.
Install gasket (22) on blower housing (19).
5.
Install motor (21) and blower housing (19) on
water
vessel
(20)
and
secure
with
six
lockwashers (18) and screws (17).
6.
Install conduit (13) in control box (11) and
secure with nut (12).
7.
Connect motor wiring (10) to control box (11)
and remove tags. See FIGURE 2-5.
8.
Install handle assembly (16) on blower housing
(19) and secure with two lockwashers (15) and
capscrews (14).
2-127