TM 10-3510-209-24
2-36. WATER HEATER BLOWER AND MOTOR ASSEMBLY
This task covers:
a. Inspection
b. Removal
c. Installation
INITIAL SETUP
Tools
General Safety Instructions
General mechanic's tool set,
SC 5180-90
WARNING
Personnel Required
High voltage is present on this equipment.
Do not perform maintenance with power on.
MOS 63J (1)
Death or serious injury may result.
Materials/Parts
Equipment Condition:
Identification tags (Item 12,
TM 10-3510-209-10, Tarp assembly removed.
App C)
Paragraph 2-38, Fuel filter removed.
INSPECTION
Inspect blower and motor assembly for damage and
unusual noise or vibration.
REMOVAL
WARNING
High voltage is present on this
equipment.
Do
not
perform
maintenance with power on. Death
or serious injury may result.
1.
Turn load limit switch (1) to OFF and disconnect
power cable (2).
2-125