TM 10-3510-209-24
2-50. WATER PUMP AND MOTOR ASSEMBLY (CONT)
REPAIR (Cont)
b.
Remove four screws (28) and switch
cover (29) from switch box cover (25).
c.
Remove two screws (30), switch (31), and
gasket (32) from switch cover (29).
d.
Tag six wires (34), remove six screws (33), and disconnect wires from switch (31).
e.
Remove four screws (35), receptacle cover (36), gasket (37), and receptacle (38) from switch box cover
(25).
f.
Tag and remove five wires (39) from receptacle (38). Replace unserviceable parts with new parts.
g.
Position five wires (39) through gasket (26) and switch box cover (25) and connect to receptacle (38).
Remove tags.
h.
Position receptacle (38), gasket (37), and receptacle cover (36) on switch box cover (25) and secure with
four screws (35).
i.
Position six wires (34) through gasket (26) and switch box cover (25). Connect wires to switch (31) and
secure with six screws (33). Remove tags.
j.
Position gasket (32) and switch (31) on switch cover (29) and secure with two screws (30).
k.
Position switch cover (29) on switch box cover (25) and secure with four screws (28).
l.
Install gasket (26) and switch box cover (25) on switch box (27) and secure with four screws (24).
2-179