TM 10-3510-209-24
2-50. WATER PUMP AND MOTOR ASSEMBLY (CONT)
SERVICE (Cont)
2.
Remove strainer cap (4), washer (5), and
strainer (6) from strainer housing (8).
3.
Remove half coupling (7) from strainer housing
(8).
4.
Remove strainer housing (8) and nipple (9) from
pump (10).
NOTE
Use thread sealer compound (Item 5,
App C) when joining pipes and
fittings.
5.
Wash strainer thoroughly with clear water.
Replace strainer if damaged or missing.
6.
Install nipple (9) and strainer housing (8) on
pump (10).
7.
Install half coupling (7) on strainer housing (8).
8.
Install strainer (6), washer (5), and strainer cap
(4) in strainer housing (8).
9.
Install bolt (2) and clamp (3) and tighten nut (1) to lock bolt.
REPAIR
1.
Repair water outlet assembly by replacing the defective component. Use these procedures in preparation for
replacing the water pump. Disassemble only as necessary.