TM 10-3510-220-10
Table 3-2. TROUBLESHOOTING (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
EXTRACTOR BASKET FAILS TO TURN.
Check lid on extractor and make sure it is closed. Inspect indicator light on
control box. Indicator should light if lid is closed.
a.
If lid is not closed, close lid and press START button.
b.
If lid is closed and extractor basket will not turn after pressing
START button, report problem to unit maintenance.
10. EXTRACTOR FAILS TO DRAIN.
Remove and inspect drain hose for kinks and/or clogged condition.
a.
If hose is clogged, remove hose and remove clog.
b.
If drain is not kinked or clogged, notify your supervisor.
11. WASHER FAILS TO FILL WITH WATER.
Step 1.
Check water pump for proper operation. Refer to malfunction 1.
a.
If water pump is not operational, notify your supervisor.
b.
If water pump is operational, proceed to next step.
Step 2.
Inspect input line for kinks and/or loose connections.
a.
Straighten lines and secure connections.
b.
If washer still fails to fill, proceed to next step.
Step 3.
Check to see if hot and cold water valves operate. Valves should
open and close when switches on the controller are activated.
a.
If valves do not operate properly, notify your supervisor.
b.
If washer still fails to fill, proceed to next step.
Step 4.
Check air pressure gage on air tank for an indication of at least 70
psi (483 kPa).
a.
If pressure is 70 psi (483 kPa) or above, proceed to next step.
b.
If pressure is below 70 psi (483 kPa) check circuit breaker on
power distribution box for the air compressor and motor start
reset button.
3-10