15. WASHER FAILS TO DRAIN.
Step 1.
Check controller switches for proper position.
a.
Position switches
b.
If switches are in
Step 2.
Check drain hose for
as needed.
proper position, proceed to next step.
kinks and/or clogged condition.
a.
If hose is kinked or clogged, disconnect hose and remove foreign
material. Connect hose and straighten kinks.
b.
If drain hose is not kinked or clogged, proceed to next step.
Step 3.
Check drain hose air valves for loose couplings and damage.
If air hose valves are loose or damaged, notify your supervisor.
16. AIR COMPRESSOR FAILS TO START.
Step 1.
Check to see if circuit breaker inside of circuit breaker box is
tripped.
a.
If circuit breaker is tripped, reset circuit breaker.
b.
If circuit breaker is not tripped and air compressor still fails to
start, proceed to next step.
Step 2.
Check motor starter reset in enclosure box located above the
circuit breaker box.
a.
If button is tripped, reset motor starter reset button.
b.
If problem still persists, notify your supervisor.