TM 10-3510-220-10
Table 3-2. Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. WASHER FAILS TO FILL WITH WATER. (Cont)
Step 5.
Check air trap and level switch tube for kinks or obstruction.
a.
Remove kink or obstruction.
b.
If water level problems persist, notify unit maintenance.
12. WASHER FILLS WITH WRONG AMOUNT OF WATER.
Step 1.
Step 2.
Step 3.
Step 4.
Inspect controller switches to determine whether switches are in
the correct positions.
a.
Set switches on controller to desired position.
b.
If problem persists, proceed to step 2.
Check air trap and level switch tube for kinks or obstruction
a.
Remove kink or obstruction.
b.
If tube contains water, this indicates an air leak, notify your
supervisor.
Check to see if hot and cold water valves operate. Valves should
open and close when switches on controller are activated.
a.
If valves do not operate properly, notify your supervisor.
b.
If valves operate properly, proceed to next step.
Check air pressure gage on air tank for an indication of at
13. WASHER FILLS WITH WRONG TEMPERATURE OF WATER.
Step 1.
Check for proper switch settings on
a.
Set switches to proper setting.
b.
If temperature problem persists,
controller.
proceed to next step.
least 70
psi (483 kPa).
a.
If pressure is below 70 psi (483 kPa), check circuit breaker on
power distribution box for the air compressor.
b.
If pressure is 70 psi (483 kPa), notify our supervisor.
3-11