TM 10-3510-220-10
2-7.
SITE SELECTION, SETUP, AND ASSEMBLY. (CONT)
(1)
(2)
(3)
(4)
g.
Make
(1)
(2)
Obtain two fuel lines (3, figure 2-13).
WARNING
Be sure that fuel lines (3, figure 2-13) do not touch or
cross water hoses, power cables, or exhaust ducts.
Melting/damage can occur causing leaking fuel and
water or electrical hazards.
Death by electrocution
fire, or explosion could result.
Connect one fuel line (3) to fuel filter inlet (2) and one fuel line to fuel
pump outlet (1).
Connect the other ends of fuel lines (3) to drum fill adapter (7). The
line from the fuel filter connects to fitting labeled SUPPLY on drum
fill adapter. The line from the bottom of fuel pump connects to fitting
labeled RETURN on the drum fill adapter.
NOTE
The drum fill adapter can be used with 55-gallon (208
liter) drums (6), 5-gallon (19 liter) cans (5), or other
fuel sources.
If a 55-gallon (208 liter) drum (6) is being used as the fuel source,
remove drum fill adapter extension (4) from the bottom of the return
port and install it in the drum fill adapter pipe. When using 5-gallon (19
liter) cans (5), the extension remains attached to the return port.
water heater fuel line connections as follows:
WARNING
Use only specified fuel (item 10, app C). Failure to do
so may result in death or serious injury to personnel or
damage to equipment.
Obtain two fuel lines (2, figure 2-14).
WARNING
Ensure that fuel lines (2, figure 2-14) do not touch or
cross water hose, power cables, or exhaust ducts.
Melting/damage can occur causing leaking fuel and
water or electrical hazards. Death by electrocution,
fire, or explosion could result.
Connect one fuel line (2) to fuel filter inlet (3) and one fuel line to fuel
pump outlet (1).
2-44