TM 10-3510-220-24
2-26. AIR COMPRESSOR (CONT)
REMOVAL
WARNING
High voltage is present on this
e q u i p m e n t.
D o n o t p e r f o rm
maintenance with power on. Death
or serious injury may result.
1.
2.
3.
4.
5.
6.
7.
8.
Turn off electrical power to air
compressor (1).
Open bleeder valve (7) on air tank (5)
and bleed air from system. Close
bleeder valve.
Disconnect compressor-to-control unit
manifold air line (11) from air
compressor (1).
Loosen captive acorn nut (8) and
remove pressure switch cover (9).
Tag and disconnect five input wires
(12) coming from conduit (14).
Remove conduit nut (13) and conduit
(14) from pressure switch (15).
Remove four nuts (16), lockwashers
(17), washers (19), and bolts (18).
Remove air compressor (1) from
platform (20).
2-84