TM 10-3510-220-24
2-27.
AIR TANK ASSEMBLY
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Equipment Condition
TM 5-6115-585-12, Generator off.
General mechanics tool kit
General Safety Instructions
WARNING
Compressed air used in this equipment can
cause death or serious injury if proper
safety precautions are not followed.
WARNING
High voltage is present on this equipment. Do
not perform maintenance with power on.
Death or serious injury may result.
REMOVAL
1.
Open petcock (4) and drain air
tank.
Ensure all air pressure is released from tank before disconnecting air
lines. Compressed air used in this equipment can cause death or
serious injury, if proper safety precautions are not followed.
2.
Disconnect air lines (2) and (6) from air tank (1).
2-89