TM 10-3510-220-24
2-40.
WATER MANIFOLD ASSEMBLY
This task covers:
a. Removal
b. Disassembly c. Repair
d. Assembly
e. Installation
f. Adjustment
INITIAL SETUP
Tools
Equipment Condition
General mechanics tool kit
TM 10-3510-220-10, Water heater off and cooled.
General Safety Instructions
Materials/Parts
WARNING
Antiseizing tape (teflon)
High voltage is present in this equipment. Do not perform
(Item 23, App C)
maintenance with power on. Death or serious injury may
Thread sealing compound
result.
(Item 5, App C)
WARNING
Water heater is hot after being used and may cause injury
to personnel if safety precautions are not followed. Allow
heater to cool before maintenance is performed.
REMOVAL
1.
Tag air lines and disconnect from two elbows (5) located on the two air actuated ball valve assemblies (16 and 34).
2.
Disconnect washer water intake hose.
3. Disconnect short water hose manifold assembly and water heater tee and remove.
4.
Remove eight nuts (7), six lockwashers (8) and clamps (9).
5.
Disconnect coupling (4) on top of manifold assembly. Remove manifold assembly from water heater.
2-136 Change 3