TM 10-3510-220-24
3-20. WATER HEATER BLOWER MOTOR ASSEMBLY (CONT)
ASSEMBLY
NOTE
Align matchmarks during assembly.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Install bearings (20) and shims (19) on aramature (18).
Install armature (18) in housing (3).
Install end plate (17) on shaft (6).
Install end plate (16) on shaft (6) and install
four screws (15).
Install impeller (14) on shaft (6) and tighten setscrew (13).
Install mounting flange (12), four lockwashers (11), and four capscrews (10).
Install key (9) and squirrel cage (8) on shaft (6) and tighten two setscrew (7).
Install yoke (5) on shaft (6) and tighten two setscrews (4).
NOTE
Align matchmarks during assembly.
Install cover (2) and four screws
(1) on housing (3).
10.
Perform follow-on installation.
Install tarp assembly (TM 10-
3510-220-10). Install water
heater blower motor
(para 2-38).
3-99