TM 10--3510--221--10
0014 00--3
LAUNDRY ADVANCED SYSTEM
INTRODUCTION TO TROUBLESHOOTING -- Continued
0014 00
TABLE 1. Analog Inputs Data -- Continued.
SENSOR
FUNCTION
RANGE
PT501
Product Air Pressure
0--200 PSIG
TE100
Ambient Air
--58 -- 212 F
TE101A
Dryer A Inlet Air Temperature
--58 -- 392 F
TE101B
Dryer B Inlet Air Temperature
--58 -- 392 F
TE102A
Dryer A Outlet Air Temperature
--58 -- 212 F
TE102B
Dryer A Outlet Air Temperature
--58 -- 212 F
TE103
Rinse 2 Tank Outlet Water Temperature
--58 -- 212 F
TE200
Still Internal Temperature
--58 -- 392 F
TE201
Still Condenser Outlet Water Temperature
--58 -- 392 F
TE202
Rinse 2 Tank Inlet Water Temperature
--58 -- 392 F
TE300
Heater Outlet Thermal Fluid Temperature
--58 -- 392 F
VREFL
PCB1 Voltage Reference Lo
0.75--0.79 VDC
VREFH
PCB1 Voltage Reference Hi
9.20--9.25VDC
TABLE 2. Discrete Inputs Data.
DEVICE
FUNCTION
STATUS
FP300
Flame Programmer Alarm Signal
OFF = Normal/ON = Fault Detected
FS100A
Detergent Pump A Flow Switch
OFF = No or Low Flow/ON = Flow
FS100B
Detergent Pump B Flow Switch
OFF = No or Low Flow/ON = Flow
FS200
Anti--foam Pump Flow Switch
OFF = No or Low Flow/ON = Flow
K100A
Drum A Inverter Fault Signal
OFF = Normal/ON = Fault
K100B
Drum B Inverter Fault Signal
OFF = Normal/ON = Fault
K104
Dryer Blowers A and B Inverter Fault Signal
OFF = Normal/ON = Fault
K200
Still Condenser Fan/Heating System Inverter Fault Signal
OFF = Normal/ON = Fault
OL101A
Water Pump A Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL101B
Water Pump B Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL104A
Dryer Blower A Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL104B
Dryer Blower B Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL105
Water Supply Pump Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected