TM 10--3510--221--10
0014 00--4
LAUNDRY ADVANCED SYSTEM
INTRODUCTION TO TROUBLESHOOTING -- Continued
0014 00
TABLE 2. Discrete Inputs Data -- Continued.
DEVICE
FUNCTION
STATUS
OL200
Still Condenser Fan Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL201
Distillate Pump Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL300
Thermal Fluid Pump Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL301
Burner Blower Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
OL500
Air Compressor Overload Relay Trip Detector
OFF = Normal/ON = Trip Detected
PBS5A
Operator Panel A SILENCE ALARM Switch
OFF = Switch Released/ON = Switch
Depressed
PBS5B
Operator Panel A SILENCE ALARM Switch
OFF = Switch Released/ON = Switch
Depressed
PBS6
EMERGENCY STOP Switch
OFF = Switch Released/ON = Switch
Depressed
PS302
Burner Fuel Pressure Switch
OFF = No or Low Fuel Pressure/ON =
Normal Fuel Pressure
PS300
Burner Blower Inlet Air Pressure Switch
OFF = No or Low Air Pressure/ON =
Normal Air Pressure
PS301
Burner Blower Outlet Air Pressure Switch
OFF = No or Low Air Pressure/ON =
Normal Air Pressure
TS300
Thermal Fluid Temperature Limit Switch
ON = Normal Temperature/OFF =
High Temperature
ZS100A
Drum Door A Position Switch
OFF= Door Open/ON= Door Closed
ZS100B
Drum Door B Position Switch
OFF= Door Open/ON= Door Closed
ZS101A
Drum Door Lock A Position Switch
OFF= Lock Retracted/ON= Lock
Extended
ZS101B
Drum Door Lock B Position Switch
OFF= Lock Retracted/ON= Lock
Extended
ZS102A
Drum A Rotation Sensor
OFF = Sprocket Spoke Not
Aligned/ON = Sprocket Spoke Aligned
ZS102B
Drum B Rotation Sensor
OFF = Sprocket Spoke Not
Aligned/ON = Sprocket Spoke Aligned
ZS103A
Drum A Balance Switch
OFF = Drum Balanced/ON = Drum
Not Balanced
ZS103B
Drum B Balance Switch
OFF = Drum Balanced/ON = Drum
Not Balanced
ZS200
Still Doors Position Switch
OFF= Door(s) Open/ON= Doors
Closed