TM 10--3510--221--10
0017 00--1
OPERATOR PANEL INDICATIONS
TROUBLESHOOTING
0017 00
THIS WORK PACKAGE COVERS:
Troubleshooting Non--displayed Faults Indicated at Operator Panel
INITIAL SETUP:
Maintenance Level
Materials/Parts
Operator
ATTENTION REQUIRED LAMP IS NOT ON
1.
Observe status of SYSTEM OPERABLE lamp (WP 0008 00, Figure 2, 2).
Is lamp on?
YES No attention is required. Return to normal operation.
NO Go to step 2.
2.
Observe status of display (6).
Does display indicate a failure message?
YES Go to step 3.
NO Notify maintenance.
3.
Replace ATTENTION REQUIRED lamp (WP 0040 00).
Does lamp come on?
YES Return to normal operation.
NO Notify maintenance.
DISPLAY DOES NOT COME ON
1.
Check status of CONTROL POWER lamp (WP 0008 00, Figure 1, 4).
Is CONTROL POWER lamp on?
YES Notify maintenance.
NO Go to CONTROL POWER LAMP IS NOT ON FAULT (WP 0017 00).