TM 10--3510--221--10
0024 00--15
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0024 00
TABLE 1. Operator PMCS -- Continued.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
35
After
Dryer inlet
screens
Ensure dryer inlet screens (1) are not
blocked with debris. If necessary clean
screens (WP 0025 00).
Screens are
blocked
36
After
Dryer outlet
guards
Ensure dryer outlet guards (2) are not
blocked with debris. If necessary clean
guards (WP 0026 00).
Screens are
blocked
37
After
Water pump
strainers
Clean/Inspect strainers (WP 0029 00).
Strainers are
damaged or not
clean
38
After
Still
Drain and clean still (WP 0030 00).
Still is not clean
39
After
Still condenser
air inlet screens
Ensure three heat exchanger air inlet
screens (3) are not blocked with debris. If
necessary clean screens (WP 0031 00).
Screens are
blocked
40
After
Drum doors
Inspect windows (4) in center of doors (5)
for cracks and signs of leakage.
Window is
cracked or
leaking
Inspect gaskets (6) on back side of doors
(5) for tears.
Gaskets are
torn
41
After
Subcooler air
inlet screen
Ensure air inlet screens (7) are not blocked
with debris. If necessary clean screen
(WP 0032 00).
Screen is
blocked
42
After
Evaporative
cooler air inlet
filters
Ensure air inlet filters (8) are not blocked
with debris. If necessary clean filters
(WP 0033 00).
Air filters are
blocked