TM 10--3510--221--10
0008 00--2
LAUNDRY ADVANCED SYSTEM DESCRIPTION AND USE OF
OPERATOR CONTROLS AND INDICATORS -- Continued
0008 00
MAIN CONTROL ENCLOSURE CONTROLS AND INDICATORS -- Continued.
Table 1. Main Control Enclosure Controls and Indicators.
INDEX
DESCRIPTION
TYPE
FUNCTION
1
MAIN DISCONNECT ON/OFF
2 Position Switch
Turns main power on or off.
2
MAIN POWER
Indicator
Illuminates when main power is applied to LADS.
3
CONTROL POWER ON/OFF
2 Position Switch
Turns control power on or off.
4
CONTROL POWER
Indicator
Illuminates when control power is applied to LADS.
5
EMERGENCY STOP
Pushbutton Switch Used to stop LADS operation under emergency
situations.
6
CIRCUIT BREAKER CB1
63 AMP, Lever
Actuated
Used to protect wiring and components in the 20 HP
inverter circuits.
7
CIRCUIT BREAKER CB2
40 AMP, Lever
Actuated
Used to protect wiring and components in the 10 HP
inverter circuits.
8
CIRCUIT BREAKER CB3
40 AMP, Lever
Actuated
Used to protect wiring and components in the Drum A
inverter circuits.
9
CIRCUIT BREAKER CB4
40 AMP, Lever
Actuated
Used to protect wiring and components in the Drum B
inverter circuits.
10
CIRCUIT BREAKER CB5
20 AMP, Lever
Actuated
Used to protect wiring and components in the water
pump circuits.
11
CIRCUIT BREAKER CB6
16 AMP, Lever
Actuated
Used to protect wiring and components in the
external water pump, distillate pump, and air
compressor circuits.
12
CIRCUIT BREAKER CB7
16 AMP, Lever
Actuated
Used to protect wiring and components in the control
power circuits.
13
CIRCUIT BREAKER CB8
16 AMP, Lever
Actuated
Used to protect wiring and components in the
external GFI circuit.