LAUNDRY ADVANCED SYSTEM OPERATION UNDER USUAL CONDITIONS
DAILY OPERATING PROCEDURES -- Continued
0010 00
DAILY OPERATING PROCEDURES -- Continued
A. System Start--up -- Continued
8. Monitor display (6) at operator panel A, it should read:
TESTING CONTROL SYSTEM
WAIT
then
PRESS TO START
9. Press MENU SELECTION switch (7) to start operation.
10. Monitor display (6), it should read:
TESTING AIR SYSTEM
AIR PRESSURE = XXX PSIG
WAIT
NOTE
It will take approximately 20 minutes for air system to pressurize when air system is
empty.
11. Continue to monitor display (6), after air system has pressurized, it should read:
FILL TANKS
WATER LEVEL LOW
OVERRIDE FILLING
or
SET WATER TEMPERATURE
SETPNT= XXX F
HEAT WATER
MODIFY SETPOINT
OVERRIDE HEATING
If WATER LEVEL LOW is displayed continue to step 12, otherwise proceed to step 15.