TM 10--3510--221--24
0030 00--2
DRYER BLOWER OVERLOAD -- Continued
0030 00
10. Position SW2 then SW1 to OFF.
11. Remove dryer outlet guard, then check for smooth rotation of wheel on dryer blower.
Does wheel rotate freely?
YES Reinstall dryer outlet guard. Go to step 12.
NO Replace dryer blower motor (WP 0130 00).
12. Check for shorted wire or connection between dryer blower contactor and dryer blower.
Are wires and connections OK?
YES Replace dryer blower motor (WP 0130 00).
NO Repair as necessary.
13. Check for shorted wire or connection between dryer blower overload relay terminals (97) and (98) and
PCB2.
Are wires and connections OK?
YES Repair as required.
NO Go to TYPICAL DISCRETE INPUT SIGNAL FAULT (WP 0107 00).
END OF WORK PACKAGE