TM 10--3510--221--24
0032 00--1
R2 TANK NOT FILLING
0032 00
THIS WORK PACKAGE COVERS:
Troubleshooting R2 Tank Not Filling Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
enclosure (WP 0010 00).
1. Observe operator panel display.
Does LT FAILURE appear?
YES Go to TYPICAL LT FAILURE FAULT (WP 0033 00).
NO Go to step 2.
2. Observe operator panel display.
Does STANDPIPE NOT EMPTYING appear?
YES Go to STANDPIPE NOT EMPTYING FAULT (WP 0058 00).
NO Go to step 3.
3. Determine if fault occurred when tank was filling during normal laundry operations or from external water
supply.
Was tank filling from external water supply?
YES Go TYPICAL TANK NOT FILLING FAULT (WP 0037 00).
NO Go to step 4.
4. Check petcock on distillate pump.
Is petcock closed?
YES Go to step 5.
NO Close petcock. Return to normal operation.
5. Check petcock on bottom of coalescer.
Is petcock closed?
YES Go to step 6.
NO Close petcock. Return to normal operation.
6. Check petcocks on subcooler.
Are petcocks closed?
YES Go to step 7.
NO Close petcocks. Return to normal operation.