TM 10--3510--221--24
0031 00--1
DRYER INLET TEMPERATURE HI OR LO
0031 00
THIS WORK PACKAGE COVERS:
Troubleshooting Dryer Inlet Temperature Hi or Lo Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
enclosure (WP 0010 00).
1. Observe operator panel display.
Does display indicate TE101 or TE102 FAILURE?
YES Go to TYPICAL TE FAILURE (WP 0035 00).
NO Go to step 2.
2. Observe operator panel display.
Does display indicate DRYER BLOWER OVERLOAD?
YES Go to DRYER BLOWER OVERLOAD FAULT (WP 0030 00).
NO Go to step 3.
3. Observe operator panel display.
Does display indicate 10 HP INVERTER FAULT?
YES Go to 10 HP INVERTER FAULT (WP 0096 00).
NO Go to step 4.
4. Check cleanliness of dryer inlet screen.
Is inlet screen clean?
YES Go to step 5.
NO Clean dryer inlet screen. Return to normal operation.
5. Check cleanliness of dryer outlet guard.
Is guard clean?
YES Go to step 6.
NO Clean dryer outlet guard. Return to normal operation.
6. Remove and inspect lint filter.
Is lint filter clean?
YES Go to step 7.
NO Clean and reinstall lint filter. Return to normal operation.