TM 10--3510--221--24
0036 00--1
TYPICAL TANK NOT EMPTYING
0036 00
THIS WORK PACKAGE COVERS:
Troubleshooting Typical Tank Not Emptying Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0273 00)
Power must be applied at main control
enclosure (WP 0010 00).
NOTE
Pressure in air system must be maintained above 80 psig while performing this procedure.
1. Observe operator panel display.
Does LTXXX FAILURE appear?
YES Go to TYPICAL LT FAILURE FAULT (WP 0033 00).
NO Go to step 2.
2. Use maintenance menu to turn on water pump and circulate water through suspect tank (WP 0010 00).
3. Verify water pump comes on.
Does water pump come on?
YES Go to step 4.
NO Go to WATER PUMP DOES NOT TURN ON FAULT (WP 0048 00).
4. Verify inlet and outlet valves on suspect tank are open.
Are both valves open?
YES Go to step 5.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
5. Observe suspect water tank.
Is water circulating into and out of tank?
YES Go to step 6.
NO Go to step 21.
6. Use maintenance menu to open drum inlet valve. Verify valve is open.
Is valve open?
YES Go to step 7.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).