TM 10--3510--221--24
0044 00--2
DRUM MOTOR STALLS DURING EXTRACT or WATER NOT
DRAINING FROM DRUM -- Continued
0044 00
7. Continue laundry cycle. During any DRAIN and EXTRACT step monitor drum outlet valve (FV108).
Is FV108 open?
YES Go to step 8.
NO Go to TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
8. Check for blockage in water plumbing between drum and still and drum and water tanks.
Is blockage found?
YES Clear blockage as required. Return to normal operation.
NO Go to DRUM INVERTER FAULT (WP 0093 00).