TM 10--3510--221--24
0055 00--2
DISTILLATE PUMP OVERLOAD -- Continued
0055 00
8. Use maintenance menu to turn on distillate pump. Observe pump operation for 2 to 3 seconds then turn off
pump.
Does does distillate pump operate?
YES Return to normal operation.
NO Go to step 9.
9. Position SW2 then SW1 to OFF.
10. Check for shorted wire or connection between distillate pump overload relay and distillate pump.
Are wires and connections OK?
YES Replace distillate pump (WP 0162 00).
NO Repair as necessary.
11. Check for shorted wire or connection between condenser fan overload relay terminals (97) and (98) and
PCB2.
Are wires and connections OK?
YES Go to TYPICAL DISCRETE INPUT SIGNAL FAULT (WP 0107 00).
NO Repair as required.
END OF WORK PACKAGE