TM 10--3510--221--24
0054 00--2
CONDENSER FAN OVERLOAD -- Continued
0054 00
10. Position SW2 then SW1 to OFF.
11. Check for smooth rotation of fan blade on condenser fan.
Does fan blade rotate freely?
YES Go to step 12.
NO Replace condenser fan motor (WP 0263 00).
12. Check for shorted wire or connection between condenser fan overload relay and condenser fan motor.
Are wires and connections OK?
YES Replace condenser fan motor (WP 0263 00).
NO Repair as necessary.
13. Check for shorted wire or connection between condenser fan overload relay terminals (97) and (98) and
PCB2.
Are wires and connections OK?
YES Go to TYPICAL DISCRETE INPUT SIGNAL FAULT (WP 0107 00).
NO Repair as required.
END OF WORK PACKAGE