TM 10--3510--221--24
0076 00--1/2 blank
TF PUMP OUTLET PRESSURE HI
0076 00
THIS WORK PACKAGE COVERS:
Troubleshooting TF Pump Outlet Pressure Hi
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
enclosure (WP 0010 00).
1. Observe operator panel display.
Does PT301 FAILURE appear?
YES Go to TYPICAL PT FAILURE (WP 0034 00).
NO Go to step 2.
2. Check for proper positions on all isolation valves (WP 0169 00).
Are isolation valves in proper positions?
YES Check for blockage in TF plumbing.
NO Properly position valve(s). Return to normal operation.
END OF WORK PACKAGE